ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-130
© 2000, ADC Telecommunications, Inc.

DLP-541

Page 1 of 16

LOOPBACK STATUS/COMMANDS

Summary:

This procedure provides instructions for displaying the currently active loopbacks for

all circuits in the system, and for enabling/disabling loopbacks.

Caution:

Do not perform a DS3 loopback when the Soneplex Broadband chassis is

connected to a DS3 CAM unit in the Soneplex CCAS system.

Note:

Edits can be made in the configuration database in one of two ways: 1) If the

complete field is highlighted, use the space bar to toggle forward or the “R” key to
reverse toggle through the options for that field. 2) If only the first space of the field is
highlighted, type in the data that applies to that field.

Note:

Edits to the configuration database can be saved after each change in one of two

ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter or Return
twice

after all selections and entries are made in the screen but before leaving the screen.

If the entries have been accepted, a message “Configuration Successful… Press Any Key
To Continue” appears on the screen.

Note:

Press CONTROL-A for help information about moving around and editing fields.

1. Use the arrow or number keys to select System Maintenance from the Main Menu. Press

Enter or Return. The System Maintenance menu is shown in

Figure 541-1

.

2. Use the arrow or number keys to select Loopback Status/Commands from the System

Maintenance Menu. Press Enter or Return. The Loopback Status/Commands menu is
shown in

Figure 541-2

.

3. Use the arrow or number keys to select High Speed Loopback Status/Commands or Low

Speed Loopback Status/Commands, then press Enter or Return. The High Speed Loopback
Status/Commands screen appears, as shown in

Figure 541-3

. The Low Speed Loopback

Status/Commands screen appears, as shown in

Figure 541-4

.

4. Low Speed only: move to the Group toggle field. Select group number 1, 2, 3, 4, 5, 6, or 7.

5. Low Speed only: move to the DS1# toggle field. Select DS1 number 1, 2, 3, or 4.

6. Use the arrow keys to move to one of the Local, Repeater, Repeater1, Repeater2, or

Remote Loopback

command toggle fields.

7. Select ACT NET, ACT CUST, SEND LPBK (at Local field only), or DEACTIVATE at each

field. Press Enter or Return. (Refer to

Table 541-1

for loopback toggle field options.) A blank

field indicates no selection.