6. Use the arrow keys to move the cursor to the Privilege Level field. Use the space bar to

select the privilege level. The lowest security level is 1, and the highest level is 5.

Users assigned Level 5 have access to all menu selections; Level 5 is assigned to the
system administrator.

Level 3 is often assigned to the operating technician; these users have access to Levels
1, 2, and 3.

Level 2 is normally assigned to a local technician; these users have access to Levels 1
and 2.

Users assigned Level 1 have access to only those menus assigned a Level 1.

7. Use the arrow keys to move to the Expiration Period field. Type in a number (0 to 999) to

represent how many days remain before the password expires. If zero is selected, the
password has no expiration period and the Number of Days Left field will display “N/A."

8. Assign the selections by pressing Enter or Return.

Stop! You have completed this procedure.

6156-A

EDIT USER ACCOUNTS

User Number : 1
User Name : SONEPLEX
Password : SONEPLEX1
Privilege Level : 5
Expiration Period: 0
Number Days Left : N/A

Press CONTROL-A For Assistance