ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-302
© 2000, ADC Telecommunications, Inc.

TAP-102

Page 3 of 11

Table 102-1. DS1 Mon Type Descriptions

MON TYPE

MEANING

LOCATION

DESCRIPTION

CVL

Code Violation Line

NEND

Count of Bipolar Violations (BPV) and excessive
zeros (EXZ) in the DS1 signal. Note: The maximum
rate of indications across HDSL loops that the far end
can report is 166.7 BPV per second (10,000 per
minute).

LOSS

Loss Of Signal
Second

NEND

A second in which one or more Loss Of Signal defects
occurred.

ESL

Errored Second Line

NEND

A second in which there occurred one or more BPVs,
one or more EXZs, or one or more LOS defects.

SESL

Severely Errored
Second Line

NEND

A second in which more than some user specified
value of CVLs or one or more LOS defects occurred.

FCP

Failure Count Path

NEND

A count of Loss Of Frame (LOF) or Alarm Indication
Signal (AIS) failures within the interval. A failure is
counted when the failure condition transitions from
OFF to ON. Failure count is independent of the
duration (in seconds) of the failure condition.

CVP

Code Violation Path

NEND

Count of (FE) Frame sync Errors in SF format or
count of CRC errors in ESF format.

AISSP

AIS Second Path

NEND

A second containing one or more AIS defects.

SASP

SEF/AIS Second Path

NEND

A second containing one or more AISSPs or one or

more SEF (Severely Errored Framing/OOF) defects.

ESP

Errored Second Path

NEND

SF framing format:

this is a second in which there

occurred one or more FE events, one or more SEF
defects, or one or more AIS defects.

ESF framing format:

this is a second in which there

occurred one or more CVP errors, one or more SEF
defects, or one or more AIS defects.

SESP

Severely Errored
Second Path

NEND

SF framing format:

this is a second in which there

occurred more than eight FE events, one or more SEF
defects, or one or more AIS defects.

ESF framing format:

this is a second in which there

occurred more than some user specified value of CVP
errors, one or more SEF defects, or one or more AIS
defects.

Note: DS1 Path Parameters are collected at the HLXC for both directions, as shown in

Figure 102-7

.

Note: Far-end parameters are not derived from defects detected in the incoming signal but rather from the
PRM (Performance Report Messages) embedded in the incoming signal from the far end. A Remote Alarm
Indication condition disallows reception of a valid PRM. The framing format must be ESF for FEND
information to be transmitted and displayed.

Note: For complete information on counts, refer to ANSI T1.231.