ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-213

© 2000, ADC Telecommunications, Inc.

DLP-570

Page 3 of 18

4. Use the arrow or number keys to select Test Access Unit Commands. Press Enter or Return.

The RTAU Configuration screen appears, as shown in

Figure 570-3

.

14868-A

RTAU CONFIGURATION

1. RTAU Unit Configuration
2. User Pattern Definition

Press CONTROL-A For Assistance

Figure 570-3. RTAU Configuration Menu

Note:

The User Pattern Definition screen is not available for the MPU 5.3 release.

5. Use the arrow or number keys to select RTAU Unit Configuration from the RTAU

Configuration menu. Press Enter or Return. The 'RTAU Config' screen appears, as shown
in

Figure 570-4

.

Note:

If the neither the RTAU or TAU are plugged into the chassis, the Test Access

Unit Status/Commands screen, shown in

Figure 570-5

, can still be accessed from the

System Maintenance menu. But in this case it cannot be configured.

However, if the TAU is plugged into the chassis, the Test Access Unit Status/Commands
screen can be configured after accessing it from the System Maintenance menu. Refer to
the Soneplex Test Access Unit Installation Instructions, listed under Related Publications
at the beginning of this manual, for more information about the TAU.

6. To prepare the RTAU for operation, set the parameters shown on the 'RTAU Config'

screen. Refer to

Figures 570-6

through

570-14

for test diagrams and mode schematics.

Refer to

Table 570-1

for details regarding parameter options. Use the arrow keys to move

from field to field. Assign the selections by pressing Enter or Return.