Ods2 alarm levels screen is shown in, Figure 561-1 – ADC Soneplex Broadband System User Manual

Page 217

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-194
© 2000, ADC Telecommunications, Inc.

DLP-561

Page 2 of 3

7. Move to the DS1 Facility Alarms toggle fields. Select CRITICAL, MAJOR, MINOR,

EVENT, or NOT RPTD for each field that you wish to change.

Reference

:

TAP-101

Alarm Troubleshooting

Note:

Default values are listed in

Table 561-1

.

8. Assign the selections by pressing Enter or Return.

Stop! You have completed this procedure.

.

6152-C

ODS2 ALARM LEVELS

Group: 3
Equipment Alarms
==============================================================
BOARD FAIL : MAJOR PROTECT COMM FAIL: MINOR
COMM FAIL : MAJOR REMOTE COMM FAIL : MINOR
CONFIG MISMATCH: MINOR VERSION MISMATCH : MINOR
HSKP1 : MINOR HSKP2 : MINOR

DS2 Facility Alarms
==============================================================
APS LIMIT : MINOR OPTICAL LOF : MAJOR
FORCE TO WORK : MINOR OPTICAL LOS : MAJOR
FORCE TO PROT : MINOR T-BER : MINOR
LASER DEGRADE : MINOR

DS1 Facility Alarms DS1 #1 DS1 #2 DS1 #3 DS1 #4
======================== ========= ========= ========= =======
LOOPED BACK : MINOR MINOR MINOR MINOR
RECEIVE LOS : MAJOR MAJOR MAJOR MAJOR
TRANSMIT EXZ : MINOR MINOR MINOR MINOR
RECEIVE AIS : EVENT EVENT EVENT EVENT

Press CONTROL-A For Assistance

Figure 561-1. ODS2 Alarm Levels Screen