Specifications, Tad-101 – ADC Soneplex Broadband System User Manual

Page 272

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-249

© 2000, ADC Telecommunications, Inc.

TAD-101

Page 1 of 9

SPECIFICATIONS

Summary:

This TAD shows technical specifications for the Soneplex Broadband system with

MPU Version 5 software in

Table 101-1

(System Specifications),

Table 101-2

(DS3 MUX

Power),

Table 101-3

(DLX Power),

Table 101-4

(C1 HLXC Power),

Table 101-5

(Version D and

E HLXC Power),

Table 101-6

(ODS2 Power),

Table 101-7

(A2 RLX Power), and

Table 101-8

(Version B RLX / RLXIOR Power).

Table 101-1. Soneplex Broadband System (V5) Specifications

PARAMETER

SPECIFICATION

REMARKS

Dimensions

Chassis (H

× W × D)

10

Ч 21.5 Ч 12 inches

(25.4

Ч 54.6 Ч 30.5 cm)

Environment

Operating Relative Humidity

5% to 95%

No condensation

Operating Temperature

–40

°F to 149°F (–40°C to 65°C)

Storage Temperature

–40

°F to 158°F (–40°C to 70°C)

Power

Input Voltage Range

–42.5 to –56.5 VDC

A and B feed

Consumption (–48 VDC):

APU

7.5 watts maximum

MPU

5 watts maximum

DS3 MUX See

Table 101-2

Per module

DLX See

Table 101-3

Per module

C1 HLXC See

Table 101-4

Version D and later HLXCs See

Table 101-5

B1 HLXR

9.9 watts

Simplex current enabled

8.3 watts

Simplex current disabled

Version D and later HLXRs,
HLXR 3192

9 watts

Simplex power enabled (D1, D2,
D2A-SP, D3, D3A, D3B HLXRs
only)

4 watts

Simplex power disabled (D2A,
D4, D4A, D4B, and Version E
HLXRs; and HLXR 3192 only)

ODS2 See

Table 101-6

A2 RLX See

Table 101-7

Version B RLX / RLXIOR See

Table 101-8

TAU

2 watts maximum

RTAU

8.2 watts maximum

Maximum Power

Determined by configuration

(continued)