ADC Soneplex Broadband System User Manual

Page 263

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-240
© 2000, ADC Telecommunications, Inc.

DLP-575

Page 2 of 5

5. Determine the Group number (1, 2, 3, 4, 5, 6, or 7) for the DS1 signal you wish to

drop/monitor. At the Group prompt, select the group number.

6. Determine the DS1 number (1 through 4) for the DS1 signal you wish to drop/monitor. At

the DS1# prompt, select the DS1 signal.

7. Use the arrow keys to move to the Drop Direction Command toggle field. Select ‘blank

field’, NONE, CUSTOMER, or NETWORK. Press Enter or Return. The following
confirmation message appears:

This Command Could Be Service Affecting...

Are You Sure? (y/n)

8. Press Enter or Return, then observe the indications on the monitoring equipment.

Note:

The Drop Direction Status field displays NONE (the default), CUSTOMER, or

NETWORK.

9. To drop other DS1 signals, repeat Steps 1 through 8, making different selections in Steps 5

(Group) and 6 (DS1 Number).

Note:

All possible DS1 Drop and Insert configurations using the TAU module are

illustrated in

Figure 575-3

for reference.

Note:

The Intrusive Test indicator on the front panel of the TAU module will light red

during any intrusive (Insert) tests.

Note:

Press the TAU’s Line Code pushbutton switch as necessary to select either B8ZS

(which lights the B8ZS indicator) or AMI for the DS1 bipolar interface.

10. To insert a Network or Customer DS1 signal:

a) Perform Steps 1 through 6.

b) Patch the front panel RX jack to the TX jack.

c) Move to the Insert Direction Command field on the screen. Select ‘blank field’,

NONE, CUSTOMER, or NETWORK. Press Enter or Return.

11. To insert an external DS1 signal:

a) Perform Steps 1 through 6.

b) Patch the external test equipment to the RX jack.

c) Move to the Insert Direction Command field on the screen. Select ‘blank field’,

NONE, CUSTOMER, or NETWORK. Press Enter or Return.

12. When you are finished using the TAU module, change the Drop Direction Command and

Insert Direction Command

fields to NONE, then disconnect any patch cords from the

front panel RX and TX jacks.

Stop! You have completed this procedure.