ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-223

© 2000, ADC Telecommunications, Inc.

DLP-570

Page 13 of 18

Table 570-1. RTAU Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

BIT ERROR SETUP FIELDS, continued

Elapsed Time

ES

Display

only

None

Six-digit counter or blank.

Blank

Elapsed Time

EFS

Display

only

None

Six-digit counter or blank.

Blank

Test Timeout in
Minutes

Input

0 to 1440

Timeout counter for test access. If the counter is set to a
number higher than “0” and then reaches “0” during test, the
Mode field will be set to DISABLE automatically. If the
counter is set to “0”, the test timeout will be turned off, and
the test will have unlimited time.

60

Measurement

Toggle

OVERVIEW: Start a measurement by selecting START at the
Measurement field. The RTAU will wait for pattern sync and
frame sync for framed patterns before starting the measurement.
After synching, the measurement display will change to
RUNNING. Stop any measurement by selecting STOP. Refer to

Figure 570-15

for an RTAU Config screen showing a test that is

starting.

Note: If the Mode is set to MONE, MONF, LOOPE, or LOOPF,
only frame sync is required before starting the measurement. If the
pattern is not in sync, then the Data Error Counts will read “N/A”
until pattern sync is established.

STOP

START

Initiate measurement.

STOP

Terminate measurement. Note: Setting the Mode field to
DISABLE also stops any measurement in progress, as if the
Measurement field had been set to STOP.

RUNNING
(display)

Measurement active.

Waiting on
Sync

Display

only

None

This parameter is displayed to the right of the Measurement
field when the Measurement field is set to START. The
WAITING ON SYNC message is display only; it only shows
up when the RTAU is waiting for either frame or pattern sync.
Examine the status section to determine what sync is needed.

Blank

Mode

Toggle

DISABLE

To end the test session, restore the tested circuit to normal
operation by selecting DISABLE.

DISABLE