ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-116
© 2000, ADC Telecommunications, Inc.

DLP-534

Page 3 of 6

Table 534-1. RLX Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

Unit Service State

Toggle

IS (In-Service)

Places the unit in service and allows

equipment alarm reporting by the MPU.
Must be set to IS for reporting of equipment
alarms.

OOS

OOS (Out-Of-Service)

Removes unit from service and stops

equipment alarm reporting by the MPU.

T1 Provision

Toggle

YES

Brings up T1 default settings and allows
configuration changes.

NO

NO

No configuration changes allowed.

T1 Service State

Toggle

Leave this field at OOS at this time to avoid undesirable reporting of alarms. Set this field to IS
after completing the configuration of the remaining fields.

Line Code

Toggle

AUTO

When the RLX line code is set to AUTO,
the module senses the line code and
switches from AMI to B8ZS if an encoded
signal is detected. After switching to B8ZS,
the RLX stays locked in this line code until
an LOS is detected at both DS1 inputs.

AMI

AMI

Alternate Mark Inversion

B8ZS

Bipolar Eight-Zero Substitution

Framing Format

Toggle

AUTO

The system automatically detects,
establishes, and displays “AUTO-NR-” and
the correct frame format (UNFRAMED, FT
ONLY, SF, or ESF).

AUTO

UNFRAMED

Unframed data pattern

Ft ONLY

Used for SLC framing

SF

Super Frame

ESF

Extended Super Frame

Network DS1 Source

Toggle

NRZ

This tells the Craft that the network DS1
source is at the backplane from the DS3
MUX.

NRZ

BIPOLAR

This tells the Craft that the network DS1
source is at the bipolar DS1 interface. If
you select this option when you are in a
Broadband chassis, you will cut off the DS1
signal. This option is used in the Loop
Extender system. See Section 4 of this
manual for information about the Extender
Card.