ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-197

© 2000, ADC Telecommunications, Inc.

DLP-562

Page 2 of 3

8. Move to the HDSL Facility Alarms toggle fields. Select CRITICAL, MAJOR, MINOR,

EVENT, or NOT RPTD for each field that you wish to change.

Reference

:

TAP-101

Alarm Troubleshooting

9. Assign the selections by pressing Enter or Return.

Stop! You have completed this procedure.

6153-C

HLX ALARM LEVELS

Group: 6 Slot: 1

Equipment Alarms
=============================================================================
COMM FAIL : MAJOR HSKP1 : MINOR PRIMARY POWER : MAJOR
LOOP REVERSAL : EVENT HSKP2 : MINOR SECONDARY POWER : MAJOR
TP/RNG REVERSAL : EVENT VERSION MISMATCH: MAJOR

DS1 Facility Alarms
=============================================================================
AIS : EVENT LOF : MAJOR T-BERL : MINOR
CUSTOMER LOOPBACK: MINOR LOS : MAJOR YELLOW : EVENT

NETWORK LOOPBACK : MINOR

HDSL Facility Alarms
=============================================================================
DC CONTINUITY : MAJOR T-BERP FE: MINOR T-SNR FE : EVENT
LOF FE : MAJOR T-BERP NE: MINOR T-SNR NE : EVENT
LOF NE : MAJOR T-PA FE : EVENT
RECOVERY : MINOR T-PA NE : EVENT

Press CONTROL-A For Assistance

Figure 562-1. HLX Alarm Levels Screen (with Default Values)