ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-183

© 2000, ADC Telecommunications, Inc.

DLP-557

Page 1 of 3

HDSL PM CONFIGURATION

Summary:

This procedure provides instructions for assigning thresholds for each HDSL facility

in the Soneplex Broadband system. You can also view or edit the HDSL Performance
Monitoring configuration for each HDSL facility in the Soneplex Broadband system from this
screen.

Note:

A “toggle” field type means the user can press the space bar to view and select the

next option that is described; or the user can press the “R” key to view and select the
previous option. An “input” field type means the user must type an entry in the field
according to the parameters described. A “fixed” field is locked, and cannot be changed by
the user.

Note:

Edits can be made in the configuration database in one of two ways: 1) If the

complete field is highlighted, use the space bar to toggle forward or the “R” key to
reverse toggle through the options for that field. 2) If only the first space or the field is
highlighted, type in the data that applies to that field.

Note:

Edits to the configuration database can be saved after each change in one of two

ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter or Return
twice

after all selections and entries are made in the screen but before leaving the screen.

If the entries have been accepted, a message “Configuration Successful…
Press Any Key To Continue” appears on the screen.

Note:

Press CONTROL-A for help information on moving around and editing fields.

1. Use the arrow keys to select Performance Monitoring from the Main Menu. Press Enter or

Return. A Performance Monitoring selection menu appears.

2. Use the arrow keys to select HDSL PM Configuration from the PM Configuration menu. Press

Enter or Return. An HDSL PM Configuration menu is shown in

Figure 557-1

.

3. Move to the Group toggle field. Select group number 1, 2, 3, 4, 5, 6, or 7.

4. Move to the Slot toggle field. Select slot number 1, 2, 3, or 4.

Reference:

TAD-106

Access Identifier

5. Move to the Mon Type Threshold toggle fields. Enter the value for each field that you wish to

change based on ranges and default values for each Mon Type listed in

Table 557-1

. Ranges are

also listed on the HDSL PM Configuration screen.