Hlx configuration, Dlp-531 – ADC Soneplex Broadband System User Manual

Page 122

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-99

© 2000, ADC Telecommunications, Inc.

DLP-531

Page 1 of 7

HLX CONFIGURATION

Summary:

This procedure provides instructions for using this menu to view or edit the

configuration for each HLX module in the chassis. This menu can also be used to equip,
provision, assign thresholds, and assign service state.

Note:

A “toggle” field type means the user can press the space bar to view and select the

next option that is described; or the user can press the “R” key to view and select the
previous option. An “input” field type means the user must type an entry in the field
according to the parameters described. A “fixed” field is locked, and cannot be changed
by the user.

Note:

Edits can be made in the configuration database in one of two ways: 1) If the

complete field is highlighted, use the space bar to toggle forward or the “R” key to
reverse toggle through the options for that field. 2) If only the first space or the field is
highlighted, type in the data that applies to that field.

Note:

Edits to the configuration database can be saved after each change in one of two

ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter or Return
twice

after all selections and entries are made in the screen but before leaving the screen.

If the entries have been accepted, a message “Configuration Successful…

Press Any

Key To Continue” appears on the screen.

Note:

Press CONTROL-A for help information on moving around and editing fields.

1. Use the arrow keys or number keys to select Unit Configuration from the Main Menu. Press

Enter or Return.

2. Use the arrow keys or number keys to select HLX Configuration from the Unit

Configuration menu. Press Enter or Return. The HLX Configuration menu is shown in

Figure 531-1

.

3. Select HLX Unit Configuration from the HLX Configuration menu. Press Enter or Return.

The HLX Unit Configuration menu is shown in

Figure 531-2

.

4. Starting at the top of

Table 531-1

and working your way to the bottom, configure the

HLXC for the group and slot selected.

5. Assign the selections by pressing Enter or Return.

6. Repeat Steps 4 through 5 for each HLXC module installed in the chassis.

Stop! You have completed this procedure.