ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-95

© 2000, ADC Telecommunications, Inc.

DLP-529

Page 4 of 4

Table 529-2. DS3 MUX Configuration Fields

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

Unit Equipment
State

Toggle

Equipped

Sets all other fields to default values,
establishes communication with the MPU,
and allows the MPU to process equipment
alarms. Module must be set to EQUIPPED
before remaining selections are allowed.

UNEQUIPPED

UNEQUIPPED

No communication with the MPU.

Unit Service
State

Toggle

IN SERVICE

Places the unit in service and allows
equipment alarm reporting by the MPU.
Must be set to IS for reporting of equipment
alarms.

OUT OF SERVICE

OUT OF
SERVICE

Removes the unit from service and stops
equipment alarm reporting by the MPU.

MUX Protect
Status

Toggle

Protected

Designates that equipment APS is available. UNPROTECTED

UNPROTECTED

Designates that equipment APS is not
available.

Facility Service
State

Toggle

IN SERVICE

Allows facility alarm reporting by the MPU.
Must be set to IS for reporting of facility
alarms.

OUT OF SERVICE

OUT OF
SERVICE

Stops facility alarm reporting by the MPU.

Transmit LBO
Setting

Toggle

IN

Inserts a Line Build Out (LBO) equivalent to
0 to 224 feet.

IN

OUT

Inserts a 225 to 450 ft. LBO in the DS3
circuit.

DS1 Loopback
Mode*

Toggle

C-bit

A type of stuff indicator bit based on TR-
TSY-000009. A C-bit is used to provide a
loopback signal.

C-BIT

S-bit

A type of stuff indicator bit invented by
NEC. An S-bit is used to provide a loopback
signal.

FEAC

FEAC (Far End Alarm and Control) is a 16-
bit code based on GR-499-CORE used to
send alarm or status information.

DS3 Framing
Format Status

Display
only

M13 or C-bit

This field displays what DS3 path framing
format has been detected. Paths with the
M13 format have their performance
monitored for near-end transmissions; paths
with C-Bit Parity format have their
performance monitored for both near- and
far-end transmissions.

None

* Note: The loopback type configured in this field involves the DS3 MUX only.