Page 5 of 9

Table 101-1. Soneplex Broadband System (V5) Specifications, continued

PARAMETER

SPECIFICATION

REMARKS

A2 RLX Module

Frame Format

SF, ESF, SLC96, and unframed

Frequency

1.544 Mbps ± 200 bps (130 ppm)

Input Signal Level

0 dB to –33 dB

Clock recovery range for loop
timing.

Line Code

AMI or B8ZS

Output Line Buildout Settings

0.0, 7.5, 15.0, and 22.5 dB

Output Signal Range

Up to 3,000 feet (914.4 meters)

Up to 6,000 feet (1,828.8 meters)

with ideal cable conditions.

Span Power

60 mA, –140 VDC max.

Up to 7 or 14 watts

Version B RLX / RLXIOR Modules

Frame Format

SF, ESF, SLC96 and unframed

Frequency

1.544 Mbps ± 130 ppm

Input Signal Level

0 dB to –33 dB

Clock recovery range for loop
timing

Line Code

AMI or B8ZS

Output Signal LBO Settings

0.0, 7.5, 15.0 and 22.5 dB

Output Signal Range

Up to 3,000 feet (914.4 meters)
over 22 AWG wire

Up to 6,000 feet (1,828.8
meters) depending on cable
characteristics

Span Power

60 mA, ±140 VDC maximum

Up to 8 or 16 watts

Streaker Module

Internal Batteries

4 AAA 1.5 volt (6 VDC)

Mounted on PCB

Jack Type

Bantam

System Input Voltage Range

42.5 to

56.5 VDC

48 VDC nominal

TAU Module

DS1 Jack Access Jack Type

Bantam

Electrical Interface

Bipolar

Impedance

100 ohms nominal

Line Code

AMI or B8ZS

Controlled by front panel switch

Line Rate

1.544 Mbps ± 130 ppm max.

(continued)