ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-264
© 2000, ADC Telecommunications, Inc.

TAD-103

Page 2 of 3

G= DS1 errors at HLXR are reported as T1-1-X-X-2 NEND PM and alarms.

Report measures the actual DS1 performance as received on transmission
from CSU H.

- OR -

DS1 errors at HLXR are reported as T1-1-X-X-2 FEND PM and alarms from
CSU H via the PRM in the FDL (Facility Data Link).

H = External CSU at H will inject PRM back to G reporting DS1 Far End Alarms.

Errors are accumulated in the transmission of the DS1 from A to H transmit
direction.

Soneplex T1 Repeater (RLX) System

A

H

CSU

CSU

RLX

B

G

14863-A

NETWORK

DS1

DS1

T1 REPEATER SPAN

Figure 103-2. Location of Critical Alarm Points on Soneplex RLX System

A = External CSU that will inject PRM (Performance Report Messages) back to B

reporting all DS1 Far End Alarms. This is due to corrupted data received at A
and reported back to B via the PRM in the FDL (Facility Data Link).

B = RLX DS1 input monitors T1-1-X-X-1 NEND PM and alarms. Report measures

the actual DS1 performance as received on transmission from CSU A.

- OR -

RLX DS1 input monitors T1-1-X-X-1 FEND PM and alarms from CSU A via
the PRM in the FDL (Facility Data Link).

G= RLX DS1 input monitors T1-1-X-X-2 NEND PM and alarms. This report

measures the actual DS1 performance as received on transmit from CSU H.

- OR -

RLX DS1 input monitors T1-1-X-X-2 FEND PM and alarms from CSU H via
the PRM in the FDL (Facility Data Link).

H= External CSU at H will inject PRM back to G reporting DS1 Far End Alarms.

This is due to corrupted data accumulated in the transmission of the DS1 from
A to H transmit direction.