ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-73

© 2000, ADC Telecommunications, Inc.

DLP-522

Page 2 of 2

10. At the far end of the circuit, insert a DS1 test signal into the DS1 input using the DS1 test set.

11. Verify that all alarm indicators on the chassis are off and the DS3 test set with DS1 option

is receiving error-free data in the DS1 signal selected for test.

12. Repeat Steps 10 and 11 for all DS1 circuits to be tested.

Stop! You have completed this procedure.

6186-B

DSX-3

CROSS-CONNECT

DSX-1

CROSS-CONNECT

MON

OUT

IN

SONEPLEX

BROADBAND

CHASSIS

DS3

TX

RX

DS3 TEST SET

TX

RX

MON

OUT

IN

OFFICE EQUIPMENT

TX

RX

DS1 TEST SET

TX

RX

SONEPLEX

BROADBAND

CHASSIS

DLX

or

RLX

Figure 522-1. Test Setup