ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-57

© 2000, ADC Telecommunications, Inc.

DLP-516

Page 2 of 6

5. Align the edges of the printed circuit card with the card guides in the chassis. Use the

injector at the bottom of the front panel to press the HLXC module into the chassis. If there
is excessive resistance to insertion, remove the module and check for improper alignment
or obstructions.

6. Perform the initial start-up test detailed in

Figure 516-3

, observing the front panel LEDs,

and verify that each LED operates as specified. Refer to

Figure 516-4

for front panel

layouts of the different HLXC versions.

If the STATUS LED is green following self-test, proceed to Step 7.

If the STATUS indicator is red, the HLXC module has failed self-test diagnostics.
Remove and then reinsert the HLXC module and then wait while the HLXC module
again performs self-test diagnostics. If the STATUS indicator turns red at the end of the
second self-test, the HLXC module is defective. Remove and replace the HLXC, and
then repeat Steps 1 through 6.

7. Press the LMPTST switch on the APU to verify that the all the indicators on the HLXC

module front panel light yellow. This indicates that each indicator is functional.

If each indicator is yellow, continue to Step 8 or 9.

If each indicator is not yellow, the HLXC module is defective. Remove and replace the
HLXC, and then repeat Steps 1 through 7.

8. Version C HLXC only: if the Loop Power option is selected in Step 3, measure DC voltage

and DC current being supplied to the HLXR. (The Version E and Version D HLXC defaults
to loop power enabled.)

Reference:

DLP-568

Version C HLXC to HLXR Voltage and Current Test

Reference:

DLP-572

Version D (or Later) HLXC to HLXR Voltage and Current Test

9. Repeat entire procedure for each HLXC module.

Stop! You have completed this procedure.