For test diagrams and mode, Figure 570-14, Dlp-570 – ADC Soneplex Broadband System User Manual

Page 251: Page 18 of 18

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-228
© 2000, ADC Telecommunications, Inc.

DLP-570

Page 18 of 18

DS3 MUX

RTAU

A

B

A

B

EQUIPMENT (E)

[NETWORK]

FACILITY (F)

[CUSTOMER]

CIRCUIT

UNDER TEST

SIGNAL

PRESENCE
DETECTOR

DS3 MUX

RTAU

EQUIPMENT (E)

[NETWORK]

FACILITY (F)

[CUSTOMER]

CIRCUIT

UNDER TEST

SIGNAL

PRESENCE
DETECTOR

11872-B

QRS

LOOPE

LOOPF

QRS

Figure 570-14. LOOPF and LOOPE

14867-A

RTAU CONFIG

EQUIPMENT SETUP

===============

Current User : CRAFT Test Circuit: 1-2
Line Code : INTERNAL Mode : SPLTE

SIGNAL GENERATOR SETUP
======================
Pattern Type : EFS -------------------------------------
Frame Format : QRS
Loop Code : NONE ---------------

BIT ERROR SETUP Error Counts Status Elapsed Time
=============== ============ ====== ============
Error Count : 0 Data : F Sync: ES :

Error Rate : OFF BPV : P Sync: EFS:

Error Locn : N/A Frame: RAI :

CRC :

COFA :

Test Timeout : 60 Measurement : START WAITING ON SYNC

In Minutes

Press CONTROL-A For Assistance

Figure 570-15. RTAU Configuration Screen (Starting a Measurement)