ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-231

© 2000, ADC Telecommunications, Inc.

DLP-572

Page 1 of 1

VERSION D (OR LATER) HLXC VOLTAGE TO HLXR TEST

Summary:

This procedure provides instructions for measuring DC voltage and DC current being

supplied by the Version D (or later) HLXC to the Version D (or later) HLXR. The V+, V–, I+,
and I– jacks provide monitor access to the voltage and current supplied to the HDSL Repeater
(HRX) (if present) and HLXR through the HDSL span. Current measurements are taken as the
voltage drop across a 10 ohm resistor.

Measure DC Voltage

1. Select –VDC on the VOM and, if so equipped, select a voltage scale of 300 volts or higher.

2. Refer to

Figure 572-1

. Insert the black test probe into the V– test jack, and insert the red

test probe into the V+ test jack. A typical meter reading should be approximately 130 VDC
(with no HRX present), or approximately 260 VDC (with HRX present).

Measure DC Current

Note:

The current test is not available on the Version G module.

3. Select –VDC on the VOM and, if so equipped, select the millivolt scale.

4. Insert the black test probe into the I– test jack, and insert the red test probe into the I+ test

jack. The millivolt reading divided by 10 is the DC current in milliamps.

Stop! You have completed this procedure.

LPBK

STAT

H

L
X

V -

I-

I+

V+

L1

L2

HDSL

RMT/
HSKP

LOSW
BER

LOSW
BER

DS1

LOS
BER

CONT
SNR

6770-A

11395-A

LPBK

STAT

H

L
X

V-

I-

I+

V+

L1

L2

HDSL

RMT/
HSKP

LOSW
BER

LOSW
BER

DS1

LOS
BER

CONT
SNR

2X

STAT

H

L

X

LPBK

LOS

BER

DS1

H
D
S
L

L1

L2

V–

V+

CONT

SNR
LOSW

BER
LOSW

BER

RMT/
HSKP

12391-A

2X

Version D HLXC

Version E HLXC

Version G HLXC

Figure 572-1. HLXC Module Front Panels