ADC Soneplex Broadband System User Manual

Page 194

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-171

© 2000, ADC Telecommunications, Inc.

DLP-551

Page 2 of 3

8. Enter "v50_dlp" source file name from the host computer and start the file transfer process.

9. Enter the Version 5.3 MPU software source file name (mpu_5xxx.bin) from the host

computer. Then start the file transfer process.

10. During the download, observe the indicators on the MPU and APU modules. During the

download, the MPU Status LED continually flashes green/yellow, and all APU indicators flash.

11. If you cancel a download, repeat Step 7 and continue. If this fails, reset the MPU and restart

this procedure from the beginning.

Note:

If the download is aborted and a "cancel" character is sent to the MPU, the MPU

will reset for a new download attempt immediately. The cancel character is part of the
XMODEM protocol supported by most software packages. If no cancel character is sent,
wait two minutes

before attempting another software download. The MPU takes two

minutes to reset when no cancel character is sent.

Note:

If the new software has been loaded into the host computer, but the download

process to the MPU has NOT been initiated, resetting the MPU allows the existing
earlier version of Version 5 software to reboot. If the download has been initiated, the
earlier version has been destroyed and a full download is necessary.

12. As the Version 5.3 MPU software download proceeds, the software existing in the MPU

module is replaced. When the download completes, the MPU automatically restarts and
runs self-test diagnostics. The MPU status indicator lights green when the download
completes successfully. Verify the MPU status indicator is green.

If Yes, proceed to Step 13.

If No, and the MPU status indicator is red, repeat Step 7 and continue.

13. Affix the new version bar code sticker to the ejector tab of the MPU.

14. Affix the "2X" sticker to the MPU faceplate, above and to the left of the "STATUS" LED,

below the ADC logo.

Note:

For V5.2 or later software, this indicates the MPU recognizes and supports two

HDSL repeaters.

Stop! You have completed this procedure.