Electromagnetic compatibility specifications, Functionality specifications protection – Rockwell Automation 193-EC4 EC4 Current Monitoring Relay User Manual User Manual

Page 120

Advertising
background image

Rockwell Automation Publication 193-UM011A-EN-P - September 2010

121

Specifications Appendix A

Electromagnetic
Compatibility
Specifications

➊Performance Criteria 1 requires the DUT to experience no degradation or loss of performance.

➋Environment 2.

Functionality
Specifications

Protection

Table 7 - Electromagnetic Compatibility Specifications

Electrostatic Discharge Immunity

Test Level:

Performance Criteria:

8kV Air Discharge
6kV Contact Discharge
1 ➊➋

RF Immunity

Test Level:
Performance Criteria:

10V/m
1 ➊➋

Electrical Fast Transient/Burst Immunity

Test Level:

Performance Criteria:

4kV (Power)
2kV (Control & Comm)
1 ➊➋

Surge Immunity

Test Level:

Performance Criteria:

2kV (L-E)
1kV (L-L)
1 ➊➋

Radiated Emissions

Class A

Conducted Emissions

Class A

Table 8 - DeviceNet Communications

Baud Rate

125 k, 250 k, 500 k

Auto-Baud Rate Identification

Yes

“Group 2 – Slave Only” device type

Yes

Polled I/O Messaging

Yes

Change of State Messaging

Yes

Cyclic Messaging

Yes

Explicit Messaging

Yes

Full Parameter Object Support

Yes

Group 4 – Off-Line Node Recovery Messaging

Yes

Configuring Consistency Value

Yes

Unconnected Messaging Manager (UCMM)

Yes

Table 9 - Protection

Trip Warning

Undercurrent

Yes

Yes

Overcurrent

Yes

Yes

Line Loss

Yes

Yes