Input assemblies – Rockwell Automation 193-EC4 EC4 Current Monitoring Relay User Manual User Manual

Page 126

Advertising
background image

Rockwell Automation Publication 193-UM011A-EN-P - September 2010

127

DeviceNet Information Appendix B

Input Assemblies

Table 20 - Assembly Object Instance 101 Data Format (“OUT A CMD”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

OutA

Table 21 - Assembly Object Instance 103 Data Format (“BASIC CMD”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

Remote
Trip

Fault
Reset

OutA

Table 22 - Assembly Object Instance 104 Data Format (“OUTPUT CMD”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

OutB

OutA

Table 23 - Assembly Object Instance 105 Data Format (“COMMAND”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

Remote
Trip

Fault
Reset

OutB

OutA

Table 24 - Assembly Object Instance 140 Data Format (“DEVICELOGIX CMD”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

Fault

Reset

OutB

OutA

1

Network
Input 7

Network
Input 6

Network
Input 5

Network
Input 4

Network
Input 3

Network
Input 2

Network
Input 1

Network
Input 0

2

Network
Input 15

Network
Input 14

Network
Input 13

Network
Input 12

Network
Input 11

Network
Input 10

Network
Input 9

Network
Input 8

Table 25 - Assembly Object Instance 50 Data Format (“TRIP STATUS”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

Faulted

Table 26 - Assembly Object Instance 51 Data Format (”TRIP WARN STATUS”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

Warning

Faulted

Table 27 - Assembly Object Instance 106 Data Format (“BASIC STATUS”)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit3

Bit 2

Bit 1

Bit 0

0

Input2

Input1

OutA_Sta
t

Warning

Faulted

Advertising