A-2 Powermonitor 3000 Data Tables

Table A.1 Summary of Powermonitor 3000 Data Tables for all Communications Options

Data Table Name and Description

Da

ta

Ac

ce

ss

In

de

xe

d

Re

ad

s

(2

)

Fi

le

No.

(3

)

(D

F1

, CS

P)

R

e

mo

te

I/O

BT

S

iz

e

A

ssy

In

st

an

ce

(

C

IP

, D

N

et

)

M

o

db

us

S

ta

rting

Ad

dr

e

ss

No

. o

f

El

eme

n

ts

Applies to

C

o

n

fig

ur

-

abl

e

Refer to

M4,

M

5

M6

M8

Remote I/O, DeviceNet, EtherNet/IP and
ControlNet I/O Messaging

R/W

-

-

I/O

1,2

-

-

(5)

• • •

(12)

Table A.2

Discrete Data

R

N9

10

3

30001

6

• • •

Table A.3

Basic Device Configuration

R/W

F10

20

4,5

40001

8 or 9

(6)

• • •

Table A.4

Date and Time

R/W

N11

12

6,7

40101

8

• • •

Table A.5

Advanced Device Configuration

R/W

N12

26

8,9

40201

26

• • •

Table A.6

Native Communication Configuration

R/W

N13

11

10,11

40301

7

• • •

Table A.7

Optional Communication Configuration

R/W

N14

24

12,13

40401

20

• • •

Table A.8

Metering Voltage, Current and Frequency Result

R

F15

38

14

30101-2

14

• • •

Table A.9

Metering Sequence Voltage and Current Results

R

F16

27

15

30201-2

11

• • •

Table A.10

Metering Power Results

R

F17

31

16

30301-2

13

• • •

Table A.11

Metering Demand Results

R

F18

25

17

30401-2

10

• • •

Table A.12

Metering Power Factor Results

R

F19

33

18

30501-2

13

• • •

Table A.13

Metering Real and Apparent Energy Results

R/W

N20

29

19,20

40501

23

• • •

Table A.14

Metering Reactive Energy and Amp-Hour
Results

R/W

N21

30

21,22

40601

23

• • •

Table A.15

Selftest/Diagnostic Results

R

N22

36

23

30601

27

• • •

Table A.16

DF1 PCCC Diagnostic Status Reply

R

(4)

-

-

-

-

• • •

Table A.17

Setpoint Setup/Read-Back Select and Status

R/W

N23

22

24,25

40701

16

• • •

Table A.18

Trend Log Configuration/Read-Back Record
Select

R/W

N24

34

26,27

40801

26

• • •

Table A.21

Trend Log Results

R

F25

48

28

30701-2

14 or 22

(7)

• • •

Table A.22

Min/Max Log Configuration/Read-Back Select

R/W

N26

13

29,30

40901

9

• • •

Table A.23

Min/Max Log Results

R

F27

28

31

30801-2

11

• • •

Table A.25

Event Log Configuration/Read-Back Record
Select

R/W

N28

9

32,33

41001

6

• • •

Table A.26

Event Log Results

R

N29

21

34

30901

14,17,18

(8)

• • •

Table A.27

User-Configured Table Setup

R/W

N30

35

35,36

41101

26

• • •

Table A.30

User-Configured Table Results

R

F31

62

37

31001-2

14 or 23

(9)

• • •

Table A.31

Write Error Status

R

N32

4

38

31101

2

• • •

Table A.32

Harmonic Analysis Configuration/Read-Back
Select

R/W

N33

14

39,40

41201

9

• • •

Table A.33

Harmonic Results; THD, Crest Factor, and More

R

F34

23

41

31201-2

9 or 10

(10)

• • •

Table A.34

Harmonic Results; Odd Harmonics 1 to 21

R

F35

39

42

-

14

• •

Table A.35

Harmonic Results; Odd Harmonics 23 to 41

R

F36

40

43

-

14

• •

Table A.36

Harmonic Results; Even Harmonics 2 to 20

R

F37

41

44

-

14

• •

Table A.37

Harmonic Results; Even Harmonics 22 to 40

R

F38

42

45

-

14

• •

Table A.38

Oscillograph Configuration/Read-Back Data
Select

R/W

N39

15

46,47

-

11

• •

Table A.39

Oscillograph Results

R

N40

61

48

-

29 or 59

(11)

• •

Table A.40

Load Factor Log Configuration/Read-Back Select

R/W

N41

16

49,50

-

6

• •

Table A.41

Load Factor Log Results

R

F42

43

51

-

14

• •

Table A.42

Transient Analysis Configuration/Read-Back
Select

R/W

F43

44

52,53

-

13

Table A.43

Advertising