Figure 3.2 menu/parameter structure – Rockwell Automation 1404-M4_M5_M6_M8 Powermonitor 3000 User Manual, PRIOR to Firmware rev. 3.0 User Manual

Page 40

Advertising
background image

Publication 1404-UM001D-EN-E - October 2004

3-14 Powermonitor 3000 Operations

Figure 3.2 Menu/Parameter Structure

Level 3

Chart Key

Default

Screen

Select

Level 1

Level 2

Level 4

Level 1

Level 2

Level 4

Default

Screen?

Display

Program

Display

Metering

Program

Password?

Metering

V,I,F

(2)

Metering

Σ Power

(4)

Harmonics

L1,L2,L3,N

(1)

IEEE %THD V

IEEE %THD I

IEC %THD V

IEC %THD I

Crest Fact. V

Crest Fact. I

TIF V

TIF I

IEEE 519 TDD

IEEE 519 P/F

Display

Harmonics

Metering

Power

(3)

Watts L1
Watts L2
Watts L3

Total Power

VARS L1
VARS L2
VARS L3

Tot. React. Pwr.

VA L1
VA L2
VA L3

Tot. App. Pwr.

True PF L1
True PF L2
True PF L3

Tot. True PF

Displ. PF L1
Displ. PF L2
Displ. PF L3

Tot. Displ. PF

Dist. PF L1
Dist. PF L2
Dist. PF L3

Tot. Dist. PF

Volts L1-N
Volts L2-N
Volts L3-N

Volts 3Ph Ave L-N

Amps L1
Amps L2
Amps L3

Amps 3Ph Ave

Amps Neutral

Volts L1-L2
Volts L2-L3
Volts L1-L3

Volts 3Ph Ave L-L

Frequency

Phase Rotation

Volts Pos Seq

Volts Neg Seq

Amps Pos Seq

Amps Neg Seq

Voltage Unbalance
Current Unbalance

kW Hours Forward
kW Hours Reverse

kW Hours Net

kVARh Forward
kVARh Reverse

kVARh Net

kVAh Net

kAh Net

Demand Amps

Demand Amps Max

Demand Watts

Demand Watts Max

Demand VAR

Demand VAR Max

Demand VA

Demand VA Max

Projected Demand I

Projected Demand W

Projected Demand VAR

Projected Demand VA

Load Factor I

Load Factor W

Load Factor VAR

Load Factor VA

Level 3

Display

Logs

Event

Log

Event n

.
.
.

Event 01

Min/Max

Log

Next Item

(Within Current Level)

Previous Item

(Within Current Level)

(1)

Voltage THD and Crest Factor Voltage are omitted for neutral channel.

(2)

Parameters displayed depend on the wiring mode.

(3)

Individual phase parameters are omitted in delta wiring modes.

(4)

Load factor parameters are available only on M6 and M8 modules.

Oldest

Most Recent

Amps L1
Amps L2
Amps L3

Average Amps

Volts L1-N
Volts L2-N
Volts L3-N

Volts Ave L-N

Volts L1-L2
Volts L2-L3
Volts L1-L3

Volts Ave L-L

Freq

Amps N

Pos Seq Current

Neg Seq Current

VA Ave 3 Ph

Demand I

Demand W

Demand VAR

Demand VA

Projected Demand I

Projected Demand W

Projected Demand VAR

Projected Demand VA

True PF L1
True PF L2
True PF L3

Total True PF

Disp. PF L1
Disp. PF L2
Disp. PF L3

% Unbal Current

Pos Seq Volts

Neg Seq Volts
% Unbal Volts

Average Frequency

Watts L1
Watts L2
Watts L3

Watts Ave 3 Ph

VARS L1
VARS L2
VARS L3

VAR Ave 3 Ph

VA L1
VA L2
VA L3

Total Disp. PF

Dist. PF L1
Dist. PF L2
Dist. PF L3

Total Dist. PF

IEEE THD L1 V

IEEE THD L1 I

IEEE THD L2 V

IEEE THD L2 I

IEEE THD L3 V

IEEE THD L3 I
IEEE THD L4 I

IEC THD L1 V

IEC THD L1 I

IEC THD L2 V

IEC THD L2 I

IEC THD L3 V

IEC THD L4 I

Crest Factor L1 V

Crest Factor L1 I

Crest Factor L2 V

Crest Factor L2 I

Crest Factor L3 V

Crest Factor L3 I
Crest Factor L4 I

Advertising