Parameter Settings

6-27

P

Water-Ultrasonic and Pressure

Sensor Combination: Air-Ultrasonic and Water-Ultrasonic

ADS recommends this option for measuring flow at a location that can experience
flows from 0 mm up to 80 percent capacity. The water-ultrasonic depth sensor
measures depths from approximately 2 inches and above; the air-ultrasonic depth
sensor measures the lower depths.

The water-ultrasonic combination sensor must be installed at the bottom of the pipe in
the center.

Water-Ultrasonic and Air-Ultrasonic

Sensor Combination: Water-Ultrasonic and Two-Wire Sensor

ADS recommends this combination for applications similar to the previous option.
However, the external 2-wire sensor would be used in place of the air-ultrasonic depth
sensor to measure low flow depths.

Sensor Combination: Air-Ultrasonic, Water-Ultrasonic, and Pressure

ADS recommends this combination for locations exhibiting flows from 0 inches up to
overflow to achieve the highest level of accuracy in measurement. The pressure
sensor measures the upper measurement range, the water-ultrasonic depth sensor

Advertising