Manning strickler coefficient table – ADS Environmental Services Portable FlowShark Pulse QR 775006 A2 User Manual

Page 197

Advertising
background image

A P P E N D I X C

Manning Strickler Coefficient Table

Consistency of channel wall

M in m1/3/s

k in mm

s

m

oot

h

glass, PMMA, polished metal surfaces

> 100

0...0.003

plastic (PVC, PE)

new steel plate with protective coating;

smoothened cement plaster

≥ 100

0.05

0.03...0.06

m

oder

at

el

y

r

ough

asphalt coated steel plate;

concrete from steel or vacuum formwork, no joints, carefully
smoothened;

planed wood, joint-free, new;

asbestos cement, new

90...100

0.1...0.3

smoothened concrete, smooth finish

planed wood, well-joint

85...90

0.4

0.6

concrete, good formwork, high cement contents

80

0.8

rough

non-planed wood; concrete pipes

75

1.5

hard-burned bricks, carefully joint;

well-manufactured ashlar facing;

concrete from joint-free wooden formwork

70...75

1.5...2.0

rolling-cast asphalt finish

70

2

well-manufactured ashlar masonry;

moderately incrusted steel pipes;

non-finished concrete, wooden formwork;

squared stones; old and swelled wood;

cement walls

65...70

3

non-finished concrete; old wooden formwork;

brickwork, no joints, finished;

quarrystone walls; less accurate

soil material, smooth (fine-grained)

60

6

Note: Rougher surfaces are difficult to measure under hydraulic conditions and, therefore, have not been included.