ADS Environmental Services Portable FlowShark Pulse QR 775006 A2 User Manual

Page 153

Advertising
background image

6-54 ADS Portable FlowShark Pulse Manual

Select store parameter to save the parameters to the memory card. This procedure
takes approximately 30 seconds; a progress bar displays for tracking purposes. Once
it is successful and complete, the display will provide notification and the memory
card
menu will appear.

Saving parameters to the memory card

The load parameters menu option displays all the program files available on the
memory card. Choosing this option transmits the selected file to the Portable
FlowShark Pulse. The name of the file required to program the unit from the memory
card is PARAMET.NIV.

Loading parameters to the memory card

The Portable FlowShark Pulse enables you to back up the parameter data from
internal memory to a memory card. This circular buffer provides storage for up to
20,000 readings and depth, velocity, flow, and temperature parameters for a 14-day
period.

Data from internal memory is always used when displaying trends through the RUN
menu.

Executing a system reset will erase all data from the internal
memory.

Saving backup data

The unit also allows you to save the day totals for up to 90 days to the memory card.
This data is saved to the TOTAL.TXT file in the DATA folder and includes the date,
time, and total based on the difference from the previous day. The totalizing time
refers to the settings designated in RUN > day totals > cycle. The memory functions
in circular mode, where newer data begins to overwrite the oldest data once the
memory becomes full. Therefore, the memory always contains the most recent 90
days of data.

Advertising