Installation 3-15

Installing sensor with integrated pressure measurement cell (1 represents sedimentation (i.e., sand or sludge))

Air-Ultrasonic Depth Sensors

Install an air-ultrasonic depth sensor using a pipe mounting system (RMS). To install
the sensor using this mounting system, run the mounting sheet located in the pipe
vertex (crown) through the cut-out in the air-ultrasonic depth sensor prior to final
assembly.

1

Ground Plate 1

2

Ground Plate 2

3

Ground Plate 3

4

Cut-out for Pipe Mounting Plate

Fastening the air-ultrasonic depth sensor to the pipe mounting system

Before clamping the system into the pipe, adjust the sensor so that it is completely
parallel with the flow surface.

When installing an air-ultrasonic depth sensor and a water-ultrasonic velocity sensor
together, locate the air-ultrasonic depth sensor upstream at least 4 inches (10 cm)
ahead of the sensor at the bottom of the pipe.

h

max

1

Installing the air-ultrasonic depth sensor