Installation 3-41 – ADS Environmental Services Portable FlowShark Pulse QR 775006 A2 User Manual

Page 78

Advertising
background image

Installation 3-41

Left

Connect the scissors jack to both sides of the final plate using the fastening clip.

Right

Turn the scissors jack clockwise all the way until it is closed before installing the
mounting system into the pipe.

Assembling the RMS 3 pipe mounting system with the scissors jack

Rotate the clamp handle of the scissors jack clockwise all the way until the scissors
are closed. Then, insert the entire system into the pipe, align it, and tighten the
clamps by rotating the clamp handle counter-clockwise

Consider the following when installing the pipe mounting system temporarily into the
pipe:

Make sure the pipe mounting system is tightly and securely seated against the
pipe wall in order to prevent the system from getting loose.

Mount the system flush against the pipe wall to minimize the risk of debris
build-up. Make sure no gap exists between the mounting plate and sensor or
pipe bottom.

Secure the sensor cable along the downstream edge of the mounting system
using cable ties.

Please refer to the list of mounting sheets on page 3-39.

Place the air-ultrasonic sensor onto the extension plate using the double mounting
plate, and make sure the sensor is installed completely parallel to the flow surface.

2

3

4

1

3

1

Mounting plate 1

2

Mounting plate 2 (base plate)

3

Mounting plate 3 (spacer plates)

4

Insertion area for the pipe mounting sheet

Constructing the mini air-ultrasonic sensor mounting plates