6-60 ADS Portable FlowShark Pulse Manual

h_crit min

Flow velocities falling below h_crit will not be calculated and, therefore, will be set to
0 (zero).

1

h_critical

2

h_crit min

3

Range of automatic Q/h relationship

4

Determination of application coefficient

Determining v_crit

Auto discharge curve

Depending on the selected setting, the unit will verify and correct (if necessary) the
values entered during the next measurement interval (automatic YES). Another
available option is for the unit to use only the values entered in the menu for Manning
Strickler, manual, or Assistant (automatic NO).

Auto discharge curve

Avoid backwater up to 0.5 inches (12 mm) deep when using the
Automatic YES option.