56 ads portable flowshark pulse manual – ADS Environmental Services Portable FlowShark Pulse QR 775006 A2 User Manual

Page 155

Advertising
background image

6-56 ADS Portable FlowShark Pulse Manual

1

Current date and time

2

Number of hours of operation remaining in the unit for taking
measurements. This reading does not include periods on standby.

3

Consumption of power (in ampere hours) during operation

4

Condition of digital input

5

Current power consumption and battery voltage. Do not allow the
battery voltage to fall below 11.5 volts before replacing or recharging
the battery.

To protect the battery, the unit will discontinue providing power to the
sensors if the voltage reaches 11.2 volts (error message: error
sensor 1
). The Portable FlowShark Pulse will turn off automatically at
11.0 volts.

6

Maximum capacity of rechargeable battery. Enter this value in PAR >
Settings > Battery
. The percentage indicates the remaining battery
life.

Viewing battery life

Advertising