Specifications

A-7

Air-Ultrasonic Depth Sensor

Measurement

Principle

Ultrasonic transit time

Measurement

Frequency

120 kHz

Protection Rating

IP68

Ex Approval

II 2 G Ex ib IIB T4 Gb

Operating

Temperature

-4° to 122° F (-20 to +50° C)
-4° to 104° F (-20 to +40° C) for applications in Ex Zone 1

Storage

Temperature

-22° to 158° F (-30° to +70° C)

Operating Pressure Maximum 14.5 psi (1 bar)

Cable Length

33/49/66/98/328 feet (10/15/20/30/50/100 m)

Cable Type

LiYC11Y 2x1.5 + 1x2x0.34

Outside Cable

Diameter

0.33 ±0.01 inches (8.4 ±0.25 mm)

Type of

Construction

Wedge sensor for installation at top (vertex) of pipe

Medium Contacting

Materials

Polyurethane, stainless steel 1.4571, PPO GF30, PA

Depth Measurement

Measurement

Range

0 to 78.7 inches (0 to 200 cm)

Dead Band

5.5 inches (14 cm)

Measurement Error less than ±0.2 inches (5 mm)

Temperature Measurement

Measurement

Range

-4° to 122° F (-20° to +50° C)

Measurement Error ±1° F (±0.5° K)