Parameter Name

Type

Requi

red

Description

REPRESENTATION_A

String

No

Specifies the numerical represen‐

tation of the multiplier input A.

Values are

UNSIGNED

,

SIGNED

and

VARIABLE

. When this parameter

is set to

SIGNED

, the adder

interprets the multiplier input A

as a signed two's complement

number. When this parameter is

set to

UNSIGNED

, the adder

interprets the multiplier input A

as an unsigned number. If

omitted, the default value is

UNSIGNED

. Use the

VARIABLE

setting to access the

SIGNED_

REGISTER_A

and the

SIGNED_

PIPELINE_REGISTER_A

parameter options for the

signa

input port.

REPRESENTATIONS_B

String

No

Specifies the numerical represen‐

tation of the multiplier input

B

port. Values are

UNSIGNED

,

SIGNED

, and

VARIABLE

. When

this parameter is set to

UNSIGNED

,

the adder interprets the

multiplier input

B

as an unsigned

number. When this parameter is

set to

SIGNED

, the adder

interprets the multiplier input

B

as a signed two's complement

number. If omitted, the default

value is

UNSIGNED

. Use the

VARIABLE

setting to access the

SIGNED_REGISTER_B

and the

SIGNED_PIPELINE_REGISTER_B

parameter options for the

signb

input port.

SIGNED_REGISTER_[]

String

No

Parameter

[A,B]

. Specifies the

clock signal for the first register

on the corresponding

sign[]

port. Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

,

CLOCK2

, and

CLOCK3

. If the corresponding

sign[]

port value is

UNUSED

, this

parameter is ignored. If omitted,

the default value is

CLOCK0

.

UG-01063

2014.12.19

ALTMULT_ADD Parameters

9-21

ALTMULT_ADD (Multiply-Adder)

Altera Corporation

Send Feedback

Advertising