background image

Parameter Name

Type

Required

Description

INPUT_B[0 … 3]_LATENCY_CLOCK

String No

Specifies the clock signal for the pipeline

register on the corresponding

datab[]

port.

Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

,

and

CLOCK2

. If omitted, the default value is

UNREGISTERED.

INPUT_B[0…3]_LATENCY_ACLR

String No

Specifies the asynchronous clear signal for

the pipeline register on the corresponding

datab[]

port. Values are

NONE

,

ACLR0

,

ACLR1

. If omitted, the default value is

NONE.

INPUT_C[0 … 3]_LATENCY_CLOCK

String No

Specifies the clock signal for the pipeline

register on the corresponding

datac[]

port.

Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

,

and

CLOCK2

. If omitted, the default value is

UNREGISTERED.

INPUT_C[0…3]_LATENCY_ACLR

String No

Specifies the asynchronous clear signal for

the pipeline register on the corresponding

datac[]

port. Values are

NONE

,

ACLR0

,

ACLR1

. If omitted, the default value is

NONE.

COEFFSEL[0…3]_LATENCY_CLOCK

String No

Specifies the clock signal for the pipeline

register on the corresponding coefficient

inputs. Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

, and

CLOCK2.

COEFFSEL[0…3]_LATENCY_ACLR

String No

Specifies the asynchronous clear signal for

the pipeline register on the corresponding

coefficient inputs. Values are

NONE

,

ACLR0

and

ACLR1

. If omitted, the default value is

NONE.

SIGNED_LATENCY_CLOCK_[]

String No

Parameter [A, B]. Specifies the clock signal

for the pipeline register on the

corresponding

sign[]

port. Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

, and

CLOCK2

. If omitted, the default value is

UNREGISTERED.

SIGNED_LATENCY_ACLR_[]

String No

Parameter

[A, B]

. Specifies the asynchro‐

nous clear signal for the pipeline register on

the corresponding

sign[]

port. Values are

NONE

,

ACLR0

, and

ACLR1

. If omitted the

default value is

NONE.

ADDNSUB_MULTIPLIER_LATENCY_

CLOCK[]

String No

Parameter

[1, 3]

. Specifies the clock signal

for the pipeline register on the

corresponding

addnsub[]

input. Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

and

CLOCK2

.

If omitted, the default value is

UNREGIS-

TERED.

6-18

ALTERA_MULT_ADD Parameters

UG-01063

2014.12.19

Altera Corporation

ALTERA_MULT_ADD (Multiply-Adder)

Send Feedback

Advertising