ALTMULT_COMPLEX Ports

Table 10-2: ALTMULT_COMPLEX IP Core Input Ports

Port Name

Required

Description

aclr

No

Asynchronous clear for the complex multiplier. When the

aclr

port is asserted high, the function is asynchronously cleared.

clock

Yes

Clock input to the ALTMULT_COMPLEX function.

dataa_imag[]

Yes

Imaginary input value for the data

A

port of the complex

multiplier. The size of the input port depends on the

WIDTH_A

parameter value.

dataa_real[]

Yes

Real input value for the data

A

port of the complex multiplier.

The size of the input port depends on the

WIDTH_A

parameter

value.

datab_imag[]

Yes

Imaginary input value for the data

B

port of the complex

multiplier. The size of the input port depends on the

WIDTH_B

parameter value.

datab_real[]

Yes

Real input value for the data

B

port of the complex multiplier.

The size of the input port depends on the

WIDTH_B

parameter

value.

ena

No

Active high clock enable for the clock port of the complex

multiplier.

Table 10-3: ALTMULT_COMPLEX IP Core Output Ports

Port Name

Required

Description

result_imag

Yes

Imaginary output value of the multiplier. The size of the output

port depends on the

WIDTH_RESULT

parameter value.

result_real

Yes

Real output value of the multiplier. The size of the output port

depends on the

WIDTH_RESULT

parameter value.

ALTMULT_COMPLEX Parameters

The following table lists the parameters for the ALTMULT_COMPLEX megafunction.

10-6

ALTMULT_COMPLEX Ports

UG-01063

2014.12.19

Altera Corporation

ALTMULT_COMPLEX (Complex Multiplier)

Send Feedback