Parameter Name

Type

Required

Description

WIDTH_B

Integer

Yes

Specifies the width of the

datab_

real[]

and

datab_imag[]

ports. Value

must be

256

bits or less. If omitted, the

default value is

18

.

WIDTH_RESULT

Integer

Yes

Specifies the width of the

result_

real[]

and

result_imag[]

ports.

Value must be

256

bits or less. If

omitted, the default value is

36

.

INTENDED_DEVICE_FAMILY

String

No

This parameter is used for modeling

and behavioral simulation purposes.

Create the

ALTMULT_COMPLEX

megafunction with the MegaWizard

Plug-in Manager to calculate the value

for this parameter.

LPM_HINT

String

No

When you instantiate a library of

parameterized modules (LPM) function

in a VHDL Design File (.vhd), you

must use the

LPM_HINT

parameter to

specify an Altera-specific parameter.

For example:

LPM_HINT = "CHAIN_

SIZE = 8, ONE_INPUT_IS_CONSTANT

= YES"

The default value is

UNUSED

.

LPM_TYPE

String

No

Identifies the library of parameterized

modules (LPM) entity name in VHDL

design files.

Design Example: Multiplication of 8-bit Complex Numbers Using

Canonical Representation

This design example uses the ALTMULT_COMPLEX megafunction to implement a complex multiplier

with an 8-bit input data width using the canonical representation. This example uses the MegaWizard

Plug-In Manager in the Quartus II software.
The following design files can be found in

altmult_complex_DesignExample.zip

:

complex_canonical.qar (archived Quartus II design files)
altmult_complex_ex_msim (ModelSim-Altera files)

Understanding the Simulation Results

10-8

Design Example: Multiplication of 8-bit Complex Numbers Using Canonical

Representation

UG-01063

2014.12.19

Altera Corporation

ALTMULT_COMPLEX (Complex Multiplier)

Send Feedback