Parameter Name

Type

Requi

red

Description

SIGNED_PIPELINE_REGISTER_[]

String

No

Parameter

[A,B]

. Specifies the

clock signal for the second

register on the corresponding

sign[]

port. Values are

UNREGISTERED

,

CLOCK0

,

CLOCK1

,

CLOCK2

, and

CLOCK3

. If the

corresponding

sign[]

port value

is

UNUSED

, this parameter is

ignored. If omitted, the default

value is

CLOCK0

.

SIGNED_ACLR_[]

String

No

Parameter

[A,B]

. Specifies the

asynchronous clear signal for the

first register on the

corresponding

sign[]

port.

Values are

NONE

,

ACLR0

,

ACLR1

,

ACLR2

, and

ACLR3

. If omitted and

corresponding

SIGNED_

REGISTER_[]

is used, the default

value is

ACLR3

.

SIGNED_PIPELINE_ACLR_[]

String

No

Parameter

[A,B]

. Specifies the

asynchronous clear signal for the

second register on the

corresponding

sign[]

port.

Values are

NONE

,

ACLR0

,

ACLR1

,

ACLR2

, and

ACLR3

. If omitted and

the corresponding

SIGNED_

PIPELINE_REGISTER_[]

is used,

the default value is

ACLR3

.

MULTIPLIER_REGISTER[]

String

No

Parameter

[0..3]

. Specifies the

clock source of the register that

follows the corresponding

multiplier. Values are

UNREGIS-

TERED

,

CLOCK0

,

CLOCK1

,

CLOCK2

,

and

CLOCK3

. If omitted, the

default value is

CLOCK0

.

MULTIPLIER_ACLR[]

String

No

Parameter

[0..3]

. Specifies the

asynchronous clear signal of the

register that follows the

corresponding multiplier. Values

are

NONE

,

ACLR0

,

ACLR1

,

ACLR2

,

and

ACLR3

. If omitted and

corresponding

MULTIPLIER_

REGISTER[]

is used, the default

value is

ACLR3

.

9-22

ALTMULT_ADD Parameters

UG-01063

2014.12.19

Altera Corporation

ALTMULT_ADD (Multiply-Adder)

Send Feedback