The following settings are applied in this mode:
• The width of the

dataa[]

input (

WIDTH_A

) must be less than or equals to 17 bits

• The width of the

datab[]

input (

WIDTH_B

) must be less than or equals to 17 bits

• The number of multipliers must be set to 2
This mode is expressed in the following equation.

The following shows the pre-adder square mode of two multipliers.

Figure 6-5: Pre-adder Square Mode

a0

b0

a1

b1

Mult0

Mult1

result

+/-

+/-

Pre-adder Constant Mode

In this mode, one multiplier operand derives from the input port, and the other operand derives from the

internal coefficient storage. The coefficient storage allows up to 8 preset constants. The coefficient

selection signals are

coefsel[0..3]

.

The following settings are applied in this mode:
• The width of the

dataa[]

input (

WIDTH_A

) must be less than or equals to 27 bits

• The width of the coefficient input must be less than or equals to 27 bits

• The

datab[]

port must be disconnected

This mode is expressed in the following equation.

The following figure shows the pre-adder constant mode of a multiplier.