Clock-domain crossing buffer, Sop alignment & atlantic conversion, Atlantic buffers – Altera POS-PHY Level 4 IP Core User Manual

Page 43

Advertising
background image

Chapter 4: Functional Description—Receiver

4–5

Block Description

December 2014

Altera Corporation

POS-PHY Level 4 IP Core User Guide

SOP8 violations. If SOPs occur less than 8 cycles apart, the err_rd_sop8 signal is
asserted but there is no impact on the received data. In 128- and 64-bit variations,
the clock-domain crossing buffer may fill faster when SOP8 violations occur.

Odd size packet violations. If an odd size packet does not end with the LSB cleared
to zero, the aN_arxerr signal is asserted on EOP. The err_rd_pad_byte_non_zero
signal is also asserted.

EOP aborts. If an EOP abort is received, the aN_arxerr signal is asserted on EOP.
The err_rd_eop_abort signal is also asserted.

DIP-4 errors (refer to

“DIP-4 Marking” on page 4–16

and

“DIP-4 Out of Service

Indication” on page 4–17

).

Reserved control words—data is dropped.

Proper training patterns. The channel aligner block requires proper training
patterns to lock, so if the transmitting device is sending bad training patterns, the
err_rd_tp

signal is asserted and the IP core does not lock.

1

Whenever the IP core aborts a packet by asserting the aN_arxerr signal (as
in the odd size packet with LSB not cleared), the resulting packet is even
sized, except in the DIP-4 optimistic mode.

f

For a more complete list of errors detected by the IP core, refer to

“Error Flagging and

Handling” on page 4–12

.

Clock-Domain Crossing Buffer

This block instantiates a clock-domain crossing buffer called alignment buffer (ABUF)
to transfer data from the rdint_clk clock domain to the rxsys_clk clock domain. The
depth of the alignment buffer is fixed at 128; the width is equal to the IP core data path
width.

f

For a description of the relationship between rdint_clk and rxsys_clk, refer to

“Clock Structure” on page 4–9

.

SOP Alignment & Atlantic Conversion

This block moves the SOP for each packet to the first-byte position on the Atlantic
interface, and aligns the data to ensure that valid data is contiguous (no IDLEs) before
sending it to the Atlantic buffer.

Atlantic Buffers

The Atlantic FIFO buffers provide the following features:

Single receive slave-source Atlantic interface on the user end

Configurable buffer size

Support for crossing clock domains