System configuration and status – Basler Electric DGC-2020HD Modbus Protocol User Manual

Page 241

Advertising
background image

9469300991 Rev A

235

DGC-2020HD Modbus

™ Protocol

Legacy Register Table

Register

Description

Type

Units

Scaling Factor R/W

Range

43456

Battery Charge Failed Contact Input

Int32 n/a

n/a

RW

-1 = None

0 = Input 1
1 = Input 2

2 = Input 3
3 = Input 4

4 = Input 5
5 = Input 6

6 = Input 7

7 = Input 8
8 = Input 9

9 = Input 10
10 = Input 11

11 = Input 12
12 = Input 13

13 = Input 14

14 = Input 15
15 = Input 16

43458

Battery Charge Failed Config Type

Int32 n/a

n/a

RW

0 = None
1 = Alarm

2 = Pre-Alarm

43460

Battery Charge Failed Time Delay

Int32 Second n/a

RW

0 - 300

43462

Fuel Leak Detect Contact Input

Int32 n/a

n/a

RW

-1 = None

0 = Input 1

1 = Input 2
2 = Input 3

3 = Input 4
4 = Input 5

5 = Input 6
6 = Input 7

7 = Input 8

8 = Input 9
9 = Input 10

10 = Input 11
11 = Input 12

12 = Input 13
13 = Input 14

14 = Input 15

15 = Input 16

43464

Fuel Leak Detect Config Type

Int32 n/a

n/a

RW

0 = None

1 = Alarm
2 = Pre-Alarm

43466

Fuel Leak Detect Time Delay

Int32 Second n/a

RW

0 - 300

43468

User Configurable Input 1 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43470

User Configurable Input 2 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43472

User Configurable Input 3 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43474

User Configurable Input 4 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43476

User Configurable Input 5 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43478

User Configurable Input 6 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43480

User Configurable Input 7 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43482

User Configurable Input 8 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43484

User Configurable Input 9 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43486

User Configurable Input 10 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43488

User Configurable Input 11 Eng Run Only

Int32 n/a

n/a

RW

0 = Always
1 = While Engine Running Only

43490

User Configurable Input 12 Eng Run Only

Int32 n/a

n/a

RW

0 = Always

1 = While Engine Running Only

43492

User Configurable Input 13 Eng Run Only

Int32 n/a

n/a

RW

0 = Always

1 = While Engine Running Only

43494

User Configurable Input 14 Eng Run Only

Int32 n/a

n/a

RW

0 = Always

1 = While Engine Running Only

43496

User Configurable Input 15 Eng Run Only

Int32 n/a

n/a

RW

0 = Always

1 = While Engine Running Only

43498

User Configurable Input 16 Eng Run Only

Int32 n/a

n/a

RW

0 = Always

1 = While Engine Running Only

System Configuration and Status

Register

Description

Type

Units

Scaling Factor

R/W

Range

43500

Rated Volts

Float

Volt

n/a

RW

1 - 99999

Advertising