TECHNICAL DATA

DESCRIPTION

Bravo 400S

Display

LCD 5.7", 65000 colors, 500 cd/m

2

Rated supply voltage

12 Vdc (9 ÷ 15 Vdc)

Consumption (valves excluded)

monitor: 0.4 A / hydraulic RCU: 1.5 A

Operating temperature

0 °C ÷ 45 °C

+32 °F ÷ +113 °F

Storage temperature

-20 °C ÷ 45 °C

-4 °F ÷ +113 °F

Digital inputs

for open collector sensors: max 2000 imp*/s

Analog input

4 ÷ 20 mA

Weight (without cables)

monitor: 1567 g (Bravo code 4674A2D21)

RCU: 1143 g

SD card reader

2 USB 2.0 ports

HOST

Protection against polarity inversion

Protection against short-circuit

17.1

The data and unit of measurement shown

Implement

Menu

Data

Min. Max.

UoM

DEFAULT

Other values that can be set / Notes

Sections
configuration

Spray spots spacing

1

1000

cm

50 cm

0.39 393.70 inches

19.68 inches

Number of sections

1

13

no

7

Selection during guided setup

Number of spraying points

--

--

--

35

Total value of spraying points installed to boom

Boom width

--

--

m

17.50 m

Value calculated automatically by multiplying the number of
spraying points by their distance

--

--

ft

57.41 ft m

Section 1 ÷ 13

1

50

no.

5

Number of spraying points for each section

Flowmeter

Type

--

--

--

Orion

462xxA4xxxx

Orion 4621xA0xxxx, Orion 4621xA1xxxx, Orion 4621xA2xxxx,
Orion 4621xA3xxxx, Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x2xxx, Wolf 462x3xxx, Wolf 462x4xxx, Wolf 462x5xxx,
Wolf 462x7xxx, Other

Constant

1

32000

pls*/l

--

Fixed settings for each flowmeter except Other

4

32000 pls*/gal

--

Minimum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Maximum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Filling flowmeter

Type

--

--

--

Orion

462xxA4xxxx

Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x4xxx, Wolf 462x5xxx, Wolf 462x7xxx, Other

Constant

1

32000

pls*/l

--

Fixed settings for each flowmeter except Other

4

32000 pls*/gal

--

Minimum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Maximum flowrate

0.1

999.9

l/min

--

0.1

264.1

GPM

--

Pressure sensor

Activation status

--

--

--

Disabled

Enabled

Type

--

--

--

466113.200

466113.500, Other

Maximum pressure

0.1

150.0

bar

--

Fixed settings for each sensor except Other

1

2175

PSI

--