Pressure sensor zero value, Advanced setup "implement – ARAG Bravo 400S Crop sprayer User Manual

Page 41

Advertising
background image

41

• Pressure sensor zero value

Fig. 139

To access this menu, the pressure sensor must be enabled (

, par. 10.1.4)

In case a pressure value other than zero is displayed

despite the absence of pressure inside the circuit,

it is necessary to perform zero calibration of the sensor.

Before carrying out any operation disable the pump by disconnecting it from the power supply.
Make sure that the pump is correctly disabled, then open the main valve and all section
valves.

Fig. 140

Fig. 141

1 Select

Pressure sensor zero value

(Fig. 139) and press

OK

.

2 The message in Fig. 140 is displayed: follow
the instructions, then start the procedure by
pressing

OK

.

3 Press

OK

to reset the pressure sensor

residual signal.

Value out of range!

If this alarm is displayed, faulty pressure
values have been detected: check the
sensor operation.
If the problem persists, check for residual
pressure in the system.

ADVANCED SETUP

"IMPLEMENT"

Par.

7.4

Exits the function
or data change

Confirm access
or data change

Scroll
(LEFT /
RIGHT)

Delete
selected
character

Increase /
Decrease
of data

Scroll
(UP /
DOWN)

Enter
selected
character