• Tank profile calibration

The calibration of the tank profile is ONLY possible if a flowmeter is installed on the system (par. 10.1.2).

Fig. 132

Before starting the procedure carry out the following operations:

1 Make sure that the main switch is in the OFF position (Fig. 132).

2 Fill the tank with clean water WITHOUT ADDING CHEMICAL SUBSTANCES.

The tank must be full. Visually check the reached level.

3 Set the output to the maximum value by keeping the control valve switch pressed
(Fig. 132, approximately 7 s).

4

Fig. 133

5

Fig. 134

4 Select the item

Tank profile calibration

(Fig. 133) and press

OK

.

Calibration starts.

5 The message in Fig. 134 is displayed: follow the
instructions, then start the procedure by pressing

OK

.

6 Start the spraying system: open, in succession,
all section valves and the main control (Fig. 132,
switches in position

ON).

7

!

Fig. 135

8

Fig. 136

The display will show in real time the quantity of
sprayed water and the calibration status (Fig. 135).

7 Once the water in tank has run out, you can

complete the procedure by pressing

OK

:

the level sensor reading must be lower than 4.5
mA and at least 10 litres must have been sprayed.

8 Press

OK

again to save the tank profile: the name

edit screen is displayed (Fig. 137).

A

B

B

E

C

D

B

A

A

Fig. 137

9 Type the name:

A

Press in succession to select the character you wish to type (UP / DOWN).

B

Press in succession to select the character you wish to type (RIGHT / LEFT).

C

Press to confirm the selected character

D

Press to delete the character before the cursor

E

Press

OK

to save the name.

11

11

Fig. 138

11 A confirmation message is displayed once the process is completed (Fig. 138).
Press

OK

or

ESC

.

Calibration is complete.

ADVANCED SETUP

"IMPLEMENT"

Par.

7.4

Exits the function
or data change

Confirm access
or data change

Scroll
(LEFT /
RIGHT)

Delete
selected
character

Increase /
Decrease
of data

Scroll
(UP /
DOWN)

Enter
selected
character