10 alarms, Nozzles alarms, Nozzle wear check – ARAG Bravo 400S Crop sprayer User Manual

Page 33: Nozzle wear limit percentage, Minimum pressure alarm • maximum pressure alarm, Minimum pressure alarm, Maximum pressure alarm, 10) if y, Advanced setup "implement

Advertising
background image

33

10.1.10 Alarms

Fig. 99

Set Bravo 400S job alarms.
For the procedure to be followed when an alarm occurs, please refer to par. 16.1 Error messages.

NOZZLES ALARMS

Fig. 100

Fig. 101

• Nozzle wear check

To configure the items on this menu, you must
enable the nozzle wear check:

Check enabled
Check disabled

This alarm can be enabled ONLY if the system
features both flowmeter and pressure sensor

• Nozzle wear limit percentage

Set the acceptable threshold: Bravo 400S compares
the effective rate read by the flowmeter and the one
calculated by the pressure sensor.
When the difference between the two rate values
exceeds the set percentage, the alarm is triggered.

Fig. 102

• Minimum pressure alarm
• Maximum pressure alarm

Allows to enable/disable minimum and maximum pressure alarms for the nozzles in use.
- Select the item you wish to set up.
- Enable/disable the alarm

(

Alarm enabled /

Alarm disabled).

- Repeat the setup for each alarm.

Outside the range set in the

Minimum pressure

/

Maximum pressure

menus

(par. 10.1.6 Nozzles data), the computer triggers an alarm.

CONTINUES > > >