Configuration, Load factory default, Import configuration – ARM Electronics XR&HD480 OSD User Manual

Page 76

Advertising
background image

User’s Manual

75

Configuration

The Configuration menu can be used to restore the default factory settings, import/export
configuration, and view/export system log. Select <Configuration> from the Main menu and
press ENTER. The following menu is displayed. Items in this menu are described in the
following subsections.

Configuration

Load Factory Default
Import Config
Export Config
System Log
Operation Log

No



Off

< Load Factory Default >

This item is used to load the factory setting. Select <Yes> to restore the factory default
setup configuration from the read-only memory. Otherwise, select <No> to cancel.

< Import Configuration >

This item allows users to load a unit configuration that was saved in an external drive. To
import a configuration that was previously exported, make sure the device that saved the
configuration is connected to the unit. Select <Import Config> from the Configuration menu
and press ENTER. The following menu is displayed.

Import Config

Config Name
xxxx-xxxx
xxx-xx

Select

No
No


Press UP / DOWN to select one of the listed configuration files, and choose <Yes> to start
importing the configuration.

NOTE:

If the imported configuration has different record mode comparing to the

DVR’s current setting, the warning message “This config has different record mode.
This will FORMAT ALL HARDDISKS.” will show.

NOTE:

Remove the ThumbDrive

®

used for importing configuration after the unit

restarts, or it will be formatted as well.