Configuration prerequisites, Configuring voice tests – H3C Technologies H3C SR8800 User Manual

Page 36

Advertising
background image

24

Configuration prerequisites

Voice tests require cooperation between the NQA server and the NQA client. Before you start voice tests,

configure a UDP listening service on the NQA server. For more information about UDP listening service
configuration, see

Configuring the NQA server

.”

Configuring voice tests

To configure voice tests:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter NQA test group view.

nqa entry admin-name
operation-tag

N/A

3.

Configure the test type as
voice and enter test type view. type voice

N/A

4.

Configure the destination

address of voice probe
packets.

destination ip ip-address

By default, no destination IP
address is configured for a test

operation.
The destination IP address must be

the same as that of the listening
service on the NQA server.

5.

Configure the destination port

of voice probe packets.

destination port port-number

By default, no destination port
number is configured.
The destination port must be the
same as that of the listening service

on the NQA server.

6.

Configure the codec type.

codec-type { g711a | g711u |
g729a }

Optional.
By default, the codec type is
G.711 A-law.

7.

Configure the advantage
factor for calculating MOS

and ICPIF values.

advantage-factor factor

Optional.
By default, the advantage factor is
0.

8.

Specify the source IP address
of probe packets.

source ip ip-address

Optional.
By default, no source IP address is
specified.
The source IP address must be the

IP address of a local interface. The
local interface must be up;

otherwise, no probe packets can

be sent out.

9.

Specify the source port
number of probe packets.

source port port-number

Optional.
By default, no source port number

is specified.

Advertising