Step Command

Remarks

12.

Configure a reaction entry for
monitoring the MOS value

(only supported in voice tests).

reaction item-number checked-element mos
threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]

NOTE:

NQA DNS tests do not support the action of sending trap messages. The action to be triggered in DNS
tests can only be the default one, none.

Only the test-complete keyword is supported for the reaction trap command in a voice test.

Configuring the NQA statistics collection function

NQA groups tests completed in a time period for a test group, and calculates the test result statistics. The

statistics form a statistics group. To view information about the statistics groups, use the display nqa
statistics command. To set the interval for collecting statistics, use the statistics interval command.
When the number of statistics groups kept reaches the upper limit and a new statistics group is to be

saved, the earliest statistics group is deleted. To set the maximum number of statistics groups that can be

kept, use the statistics max-group command.
A statistics group is formed after the last test is completed within the specified interval. When its hold time
expires, the statistics group is deleted. To set the hold time of statistics groups for a test group, use the

statistics hold-time command.
To configure the NQA statistics collection function:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter NQA test group view.

nqa entry admin-name
operation-tag

N/A

3.

Enter test type view of the test

group.

type { dlsw | dns | ftp | http |
icmp-echo | snmp | tcp |
udp-echo | udp-jitter | voice }

N/A

4.

Configure the interval for
collecting the statistics of test

results.

statistics interval interval

Optional.
60 minutes by default.

5.

Configure the maximum
number of statistics groups

that can be kept.

statistics max-group number

Optional.
2 by default.
To disable collecting NQA

statistics, set the maximum number
to 0.

6.

Configure the hold time of

statistics groups.

statistics hold-time hold-time

Optional.
120 minutes by default.


Advertising