GT 600 / 601 Engineer’s Reference Guide

6 Wire Remote Keypads

A six core connection will be required between the control panel and remote
keypad(s), keypads may be in a 'daisy chain' or ‘star’ format.

Note:

Each keypad has address jumpers labled A1 to A4. Please select the
correct address for each keypad before the system is powered up. If
more than four keypads are to be used, then ‘Mult’ (Program Keypad)
has to be selected to ON.

Note:

Contour keypads may be fitted with ACE or Prox and an additional
jumper labled NVM 31 keyfobs or G-Tag Prox Tags may be
programmed on to individual user codes. With the NVM jumper in
place the ACE/Prox memory will be cleared when power is applied
therefore this jumper should be removed on completion of the
installation.

Fig 2. 6 Wire RKP Connection

SPKR DATA DATA CLK 0V 12V

- B A

DATAB DATAA CLK OV 12V SPKR

GT 600 / 601 Control Panel

RKP

AUX+