Page, Detector using wired biscuit, Pa using wired biscuit – RISCO Group Gardtec GT600 User Manual

Page 114: Y = yellow b = blue w = white key

Advertising
background image

Page

112

GT 600 / 601 Engineer’s Reference Guide

ID Expander Detector Wiring

One ID Expander Card may be fitted to the

GT 600 control panel giving 8 panel zones

plus up to 30 ID zones using industry standard ID Biscuits or ID Detectors. ID zones
numbers are 21 through to 50. Two ID Expander Cards may be fitted to the

GT 601

Control Panel. The 2nd ID card will be zones 51 - 80.

Typical wiring for ID Biscuits is shown below.

Fig 12.

Fig 13.

Fig 14.

Note: For ID pairing, biscuit numbers MUST be in sequence...
Example: PIR1 = Biscuits 1& 2, PIR2 = Biscuits 3 & 4 etc...

+

-

TAMPER

ALARM

Supply+

Supply-

L+

L-

White

Blue

Yellow

ID Biscuit

Detector Using Wired Biscuit

Yellow

Blue

White

Reed Switch

(PA / Contact)

Supply+

Supply-

L-

L+

PA Using Wired Biscuit

Red +12V
Black 0V

Blue > ID-

Yellow > ID +

Y B W

B

W

Y

Y = Yellow

B = Blue

W = White

Key -

+ - Tamper Alarm Fault/Mask

Advertising