78

GT 600 / 601 Engineer’s Reference Guide

6)

Press Yes. The display will show:-

7)

Press No. The display will show:-

8)

Press Yes. The display will show:-

9)

Press Yes. The display will show:-

A PSU/Battery test will be carried out at the time
interval set here and each time you leave Engineer
Mode. This may be turned Off by setting the Time
interval to 0 (zero).

10)

Press No twice. The display will show:-

11)

Enter the time you require (in hours) followed by
Yes. The display will show:-

12)

Press Yes. The display will show:-

In this example any voltage over 14V or below
11.8V will create a warning when the PSU test
is performed by the system.

13)

To change these limits. Press No until the required
setting for V.Max is displayed, then press Yes.
The display will show, for example:-

List
Event Log ?

Change / List
Diagnostics ?

PSU . . .
Diagnostics ?

PSU Test Time
= 01 Hrs

PSU Test Time
= _ _ Hrs

Change / List
Test Limits ?

Aux. Vmax = 14.0
Aux. Vmin = 11.8.

Aux. VMax = 14.0V
Aux. VMin > 11.8V